BZQBS - ACID HEMATOXYLIN SOLUTION, H4630

  • MSDS: BZQBS
  • Manufacturer: SIGMA CHEMICAL CO
  • Product Name: ACID HEMATOXYLIN SOLUTION, H4630
  • National Stock Number: 6810-00N064471
Product Identification

Product ID:ACID HEMATOXYLIN SOLUTION, H4630
MSDS Date:05/16/1995
FSC:6810
NIIN:00N064471
MSDS Number: BZQBS

Responsible Party
SIGMA CHEMICAL CO
ST LOUIS, MO 63178
US

Emergency Phone: 314-771-5765

Info Phone: 800-325-3010

Cage: 0DK69

Contractor
SIGMA CHEMICAL CO SIGMA DIAGNOSTICS DIV
ST LOUIS, MO 63103-2530 US

Telephone: 314-771-5765

Cage: 0DK69

Ingredients

IODIC ACID, SODIUM SALT; (SODIUM IODATE)

CAS: 7681-55-2

RTECS: NN1400000

Fraction By Weight: 0.2%

OSHA PEL N/K

ACGIH TLV: N/K


AMMONIUM ALUMINUM SULFATE; (ALUMINUM AMMONIUM SULFATE)

CAS: 7784-26-1

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: N/K


CITRIC ACID

CAS: 77-92-9

RTECS: GE7350000

Fraction By Weight: 0.1%

OSHA PEL N/K

ACGIH TLV: N/K


CHLORAL HYDRATE

CAS: 302-17-0

RTECS: FM8750000

Fraction By Weight: 5%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:HARMFUL IF SWALLOWED, INHALED OR
ABSORBED THROUGH SKIN. CAUSES EYE & SKIN IRRITATION. VAPOR OR MIST
IS IRRITATING TO EYES, MUCOUS MEMBRANES & UPPER RESPIRATORY TRACT.
EXPOSURE CAN CAUSE: GASTROI NTESTINAL DISTURBANCES, NAUSEA,
HEADACHE & VOMITING, CENTRAL NERVOUS SYSTEM DEPRESSION. CHRONIC:
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:POSSIBLE MUTAGEN. TARGET ORGAN(S):
CENTRAL NERVOUS SYSTEM.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INGEST:WASH OUT MOUTH W/WATER PROVIDED PERSON IS CONSCIOUS.
CALL MD. SKIN:FLUSH W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. REMOVE CONTAMINATED CLOTHING & SHOES. CALL MD.
INHAL:REMOVE TO FRESH AIR. IF BREATHING BECOMES DIFFICULT, CALL
MD. EYES:FLUSH W/COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
ASSURE ADEQUATE FLUSHING BY SEPARATING EYELIDS W/FINGERS. CALL MD.

Fire Fighting

Extinguishing Media:WATER SPRAY, CARBON DIOXIDE, DRY CHEMICAL POWDER OR
APPROPRIATE FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS TOXIC FUMES UNDER FIRE CONDITIONS.

Accidental Release

Spill Release Procedures:WEAR NIOSH/MSHA APPROVED SCBA, RUBBER BOOTS &
HEAVY RUBBER GLOVES. ABSORB ON SAND OR VERMICULITE & PLACE IN
CLOSED CONTAINERS FOR DISPOSAL. VENTILATE AREA & WASH SPILL SITE
AFTER MATERIAL PICKUP IS CO MPLETE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AIR & LIGHT SENSITIVE.
Other Precautions:HARMFUL BY INHALATION, IN CONTACT W/SKIN & IF
SWALLOWED. IRRITATING TO EYES, RESPIRATORY SYSTEM & SKIN. POSSIBLE
RISK OF IRREVERSIBLE EFFECTS. POSSIBLE MUTAGEN.

Exposure Controls

Respiratory Protection:WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:MECHANICAL EXHAUST REQUIRED.
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . WEAR SUITABLE PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MATLS TO AVOID:PERMANGANATES & ALCOHOL.

Chemical Properties

Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
ALKALIS, ALKALINE EARTHS, ALKALI CARBONATES, SOLUBLE BARBITURATES,
BORAX, TANNIN, IODIDES, OXIDIZING AGENTS, (SUPP DATA)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:TOXIC FUMES OF: CARBON MONOXIDE,
CARBON DIOXIDE, HYDROGEN CHLORIDE GAS.

Disposal

Waste Disposal Methods:DISSOLVE OR MIX MATERIAL W/COMBUSTIBLE SOLVENT &
BURN IN A CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER & SCRUBBER.
OBSERVE ALL FEDERAL, STATE & LOCAL ENVIRONMENTAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.